Ultrasonic flue gas velocity detector

This system provides users with flow measurement solutions beyond traditional methods such as matrix pilot tubes and thermal balance, especially in sites of low vel- ocity, wet flue gas and corrosive exhaust gas ( waste power plant).

Feature


☆ Can achieve high precision measurement at very low flue gas velocity

☆ On-line automatic calibration function of the whole system

☆ Wide measuring range to meet different field condition

☆ With purging isolation unit,low maintenance 

☆ Easy installation & maintenance, can install two-side or single side

☆ Titanium probe can be used for corrosive smoke


Principle


 This system measures the flue gas emission according to the principle of ultraso-

nic propagation time difference. The ultrasonic  sensor transmits waves in opposite dir-

ections to each other, then ultrasonic waves in the two directions produce a time diffe-

rence. The flow rate is calculated according to the difference.

        The flow velocity measurement is related to the up-flow transmission time T1, th-

e backward flow transmission time T2,the length of the transmission path and the ang-

le between the smoke flow. It has nothing to do with temperature, pressure,compositi-

on of the flue gas.

        According to the transmission speed of ultrasonic reflue gas, the temperature of 

flue gas is calculated. Combined with the cross-sectional area of flue, the volume flow 

rate of flue gas is calculated. 


System composition


 This system consists of two transmitters ( receivers) and control units.The control

 unit is used for signal input and output, for calculating volume flow to reference condi-

tions and for rapid processing via LC display.


Installation of transmitter ( receiver ) unit


        1.   Two-side installation: two transmitter (receiver) units are installed on either side

 of the flue at a specific angle to the direction of the gas flow.

        2.   Single side installation: only one transmitter(receiver) is installed on the flue at 

a specific angle to the direction of the gas flow.


                              

Measuring object                        Flue gas velocity,Volume flow,Temperature,Pressure

Measuring range                         0~40m/s

Flue diameter                              0.14~13m

Resolution ratio                          0.001m/s 

Detection limit                           ≤0.1m/s

RSD                                            ±0.1m/s

Zero drift                                   ≤±1%

Response time                          5s(adjustable)

Working conditions

Flow gas temperature              -40~450℃

Pressure                                   -6.1~10kPA

Humidity                                  0~100%RH

Environment temperature       -40~60℃

Electronic Control Unit

Output                                   4~20mA  4 ways

Communication                     RS232

Power supply                         220V 50HZ

Grade                                     IP65 Ex dbIIB T4Gb